型號
Model |
名稱
Descriptions |
使用范圍
Use scope |
MHYV
|
聚乙烯絕緣聚氯乙烯護套礦用通信電纜PE insulated PVC sheathed communication cables for coal mines
|
用于平巷、斜巷及機電硐室
Served in level,slanted channels and power house |
MHJYV
|
加強型線芯聚乙烯絕緣聚氯乙烯護套礦用通信電纜Reinforced core PE insulated PVC sheathed communication cables for coal mines
|
用于機械損傷較高的平巷和斜巷
Served in level and slanted channels where mechanical damage is frequent |
MHYBV
|
聚乙烯絕緣鍍鋅鋼絲編織鎧裝聚氯乙烯護套礦用通信電纜PE insulated galvanized steel wire weave armored PVC sheathed communication cables for coal mines
|
用于機械沖擊較高的平巷和斜巷
Served in level and slanted channels where mechanical damage is frequent |
MHYAV
|
聚乙烯絕緣鋁-聚乙烯粘護層聚氯乙烯護套礦用通信電纜PE insulated Al/PE binding layer PVC sheathed communication cables for coal mines
|
用于較潮濕的斜井和平巷
Served in level and slanted channels with high humidity |
MHYA32
|
聚乙烯絕緣鋁-聚乙烯粘結護層鋼絲鎧裝聚氯乙烯護套礦用通信電纜PE insulated Al/PE binding layer steel wire armored PVC sheathed communication cables for coal mines
|
用于豎井或斜井
Served in shaft and slanted shaft |
電纜長期允許工作溫度 Long-term service temperature of the cable conductor
|
-40℃-+50℃
|
電纜敷設溫度 Cable laying temperature
|
≥-10℃
|
+25℃時環境相對濕度
Environment relative humidity at 25℃ |
≤95%
|
電纜的最小彎曲半徑 Minimun bending radius
|
MHYV及MHJYV型電纜為電纜外徑的10倍,其它型號為外徑的15倍 10 times of the cable outer diameter of MHJYV, and 15times for the rest
|
型號
Model |
規格
Specifications |
導體結構(根/直徑)mm
Conductor structure(number/diameter) |
MHYV
|
1x2、2x2、1x4、5x2
|
7/0.28
|
MHJYV
|
1x2、2x2
|
4/0.28銅線+3/0.28鋼線 4/0.28
copper wire +3/0.28 steel wire |
MHYBV
|
5x2、10x2、20x2
|
1/0.8
|
MHYAV
|
20x2、30x2、50x2
|
|
MHYA32
|
30x2、50x2、80x2
|
型號
Model |
20℃時導體直流電阻
DC resistance of conductor at 20℃ ≤Ω ( , /km) |
固有衰減(800Hz)
Intrinsic attenuation ≤( ,dB/km) |
MHYV
|
45
|
1.10
|
MHJYV
|
73
|
1.30
|
MHYBV MHYAV MHYA32
|
36.7
|
0.95
|
序號
Serial number |
項目
Items |
技術性能
Technical performances |
1
|
+20℃線芯直流電阻(≤Ω/Km)
Line core DC resistance at 20℃ |
見上表 See above table
|
2
|
電纜固有衰減(≤dB/Km)
Cable intrinsic attenuation |
見上表 See above table
|
3
|
+20℃絕緣電阻(≥MΩ Km) Insulating resistance at 20℃
|
3000
|
4
|
lmin工頻交流電壓試驗
lmin power frequency alternating current pressure test |
1500V不擊穿(50Hz)
1500V Does not penetrate |
5
|
遠端串音衰減(≥dB/500)
Far-end crosstalk attenuation |
70(800Hz)
|
6
|
電感(≤μH/Km)
Inductance |
800(800Hz)
|
7
|
電纜工作電容(≤μF/Km)
Cable service capacity |
0.06(800Hz)
|
8
|
工作對直流電阻差(≤%環阻)
DC resistance difference |
2
|
9
|
單根垂直燃燒試驗
Combustion for single cable test |
MT386
|
10
|
成束燃燒試驗
Combustion for bunched cable test |
符合GB/T18380標準中B類成束燃燒試驗要求
Conforms to GB/T18380 standard B kind becomes ties the burning test |